01
A licensed Russian pharmacy buys it for you.
No grey-market middlemen, no warehouses we can't audit. Retail purchase, on demand, against your order.

Pharmacy item
SKU 74478
Other products by → OK Biotech Co., Ltd
Manufacturer leaflet
Facts from the printed manufacturer leaflet. Sections vary by drug — we only show what's actually in the box.
Determination and monitoring of glucose levels in whole capillary blood in individuals with diabetes mellitus. The system is intended for use outside the human body (for in vitro diagnostics) by patients with diabetes mellitus independently, as well as with the assistance of healthcare professionals for monitoring the effectiveness of diabetes control measures at the patient's treatment location, as a multi-user system.
Определение и контроль уровня глюкозы в цельной капиллярной крови у людей с сахарным диабетом. Система предназначена для использования вне тела человека (для диагностики in vitro) пациентами с сахарным диабетом самостоятельно, а также с помощью медицинских работников для мониторинга эффективности мер по контролю сахарного диабета по месту лечения пациентов, как многопользовательская система.
Test strip insertion slot.
Insert the strip here.
The device will turn on automatically.
The lancing device and lancets are intended for obtaining blood for testing.
IMPORTANT INFORMATION
1. The lancet is for single use only.
2. Always keep the lancing device and lancets clean.
3. Carefully remove the used lancet from the lancing device.
4. Store lancets out of reach of children.
IMPORTANT:
The lancing device and lancets are intended for use by one person only.
DO NOT SHARE with anyone, even family members!
DO NOT USE for multiple patients!
INTERPRETATION OF TEST RESULTS
In healthy adults, fasting blood glucose levels should be less than 6.1 mmol/L, and less than 7.8 mmol/L two hours after eating.*
To determine your target blood glucose level, consult your endocrinologist.
If your blood glucose value falls outside the above ranges or significantly differs from your previous results, check the following:
1. A significant amount of time should not pass between taking the test strip from the vial and applying a drop of blood to the strip.
2. The drop of blood must be sufficient to fill the entire capillary of the strip.
3. After taking the test strip from the vial, the vial cap must be closed immediately.
4. Do not use test strips that are past their expiration date.
5. Test strips should be stored at a temperature of +4°C to +40°C.
Perform testing with a control solution. If the measurement result using the control solution is within the normal ranges indicated on the test strip vial, then perform a blood test using a new test strip.
If the repeated blood test result exceeds the established limits of > 6.1 mmol/L fasting and > 7.8 mmol/L two hours after eating, consult a doctor immediately.
*Algorithms for specialized medical care for patients with diabetes mellitus edited by I.I. Dedov, M.V. Shestakova. Diagnostic criteria for diabetes mellitus and other glycemic disorders: p.9, 7th edition 2015.
Разъем для ввода тест полоски.
Вставьте полоску сюда.
Прибор включится автоматически.
Скарификатор и ланцеты предназначены для получения крови для теста.
ВАЖНАЯ ИНФОРМАЦИЯ
1. Ланцет предназначен только для одноразового использования
2. Всегда храните скарификатор и ланцеты в чистоте.
3. Аккуратно удаляйте использованный ланцет из скарификатора.
4. Храните ланцеты в недоступном для детей месте.
ВАЖНО:
Скарификатор и ланцеты предназначены для пользования только одним лицом.
НЕ ДАВАЙТЕ пользоваться никому, даже членам своей семьи!
НЕ ИСПОЛЬЗОВАТЬ для нескольких пациентов!
ИНТЕРПРЕТАЦИЯ РЕЗУЛЬТАТА ТЕСТА
У здоровых взрослых людей уровень глюкозы крови утром натощак должен быть менее 6,1 ммоль/л, и менее 7,8 ммоль/л через два часа после еды.*
Для определения вашего целевого показателя глюкозы крови обратитесь к вашему эндокринологу.
Если значение глюкозы крови выходит за рамки вышеприведенных цифр или значительно отличаются от ваших предыдущих результатов, проверьте следующие моменты:
1. Не должно пройти много времени между моментом взятия тест-полоски из флакона и нанесением капли крови на полоску.
2. Капля крови должна быть достаточной для того, чтобы заполнился весь капилляр полоски.
3. После взятия тест-полоски из флакона, необходимо сразу закрыть крышку флакона.
4. Не использовать тест-полоски с истекшим сроком годности.
5. Тест-полоски должны храниться при температуре +4°С +40 °С.
Проведите тестирование с контрольным раствором. Если результат измерения с использованием контрольного раствора находится в пределах нормальных величин, указанных на флаконе с тест-полосками, то сделайте тест с кровью, взяв новую тест-полоску.
Если повторный результат тестирования вашей крови выходит за установленные границы> 6,1 ммоль/л натощак и >7,8 ммоль/л через 2 часа после еды, то немедленно обратитесь к врачу за консультацией.
*Алгоритмы специализированной медицинской помощи больным сахарным диабетом под ред. И.И. Дедова, М.В. Шестаковой. Диагностические критерии сахарного диабета и других нарушений гликемии: стр.9, 7-й выпуск 2015 г.
The blood glucose monitoring system is not intended for screening or diagnosing diabetes mellitus and for measuring blood glucose levels in newborns.
BUILT-IN MEMORY
The Diacont Connect glucometer automatically saves 1000 test results, allowing you to view them in chronological order. The device also calculates and displays average values for 7, 14, 21, and 28 days. You can view test results by switching to memory mode.
IMPORTANT INFORMATION:
If you do not press any buttons on the glucometer, "OFF" will appear on the screen after 1 minute, and the device will automatically turn off.
Working with the Diacont Connect Mobile Application
Getting Started
To use the Diacont Connect mobile application, you need to download it on Apple devices or devices with the Android operating system using the App Store or Google Play store.
STORAGE CONDITIONS
Storage conditions for the Diacont Connect blood glucose monitoring system:
Storage temperature of the system from +4°C to +30°C at a relative humidity of 10-85%.
• Do not allow drops and strong impacts.
• Do not expose the system to sunlight.
• Do not allow water to come into contact with the device.
The storage and operation of the mobile application are carried out on Apple devices with the iOS operating system and devices with the Android operating system.
Your glucometer is an accurate medical device; handle it with care.
Система контроля уровня глюкозы в крови не предназначена для скрининга или диагностики сахарного диабета и для измерения уровня глюкозы в крови у новорожденных.
ВСТРОЕННАЯ ПАМЯТЬ
Глюкометр Diacont Connect автоматически сохраняет 1000 результатов тестирования, позволяя просматривать их в хронологическом порядке. Прибор также рассчитывает и отображает средние значения за 7, 14, 21 и 28 дней. Вы можете просмотреть результаты теста, перейдя в режим памяти.
ВАЖНАЯ ИНФОРМАЦИЯ:
Если вы не нажимаете никакие кнопки глюкометра, то в течение 1 минуты на экране появится «OFF», и прибор автоматически выключится.
Работа с Программным мобильным приложением Diacont Connect
Начало работы
Для работы с Программным мобильным приложением Diacont Connect нужно загрузить его на устройства Apple или на устройства с операционной системой Android используя платформу магазина App Store или Google Play
УСЛОВИЯ ХРАНЕНИЯ
Условия хранения системы контроля уровня глюкозы в крови марки «Diacont» Connect:
Температура хранения системы от +4°С до +30°С при относительной влажности 10-85%.
• Не допускайте падений и сильных ударов.
• Не допускайте нахождение системы на солнце.
• Не допускайте попадания воды на изделие.
Хранение и эксплуатация мобильного приложения осуществляется на устройствах Apple с операционной системой iOS и устройствах с операционной системой Android.
Ваш глюкометр - точный медицинский прибор, обращайтесь с ним аккуратно.
A bruise may form at the site of blood collection. If a bruise is present, it is better to choose another site.
В месте взятия крови может образоваться кровоподтек. При наличии кровоподтека лучше выбрать другое место.
GLUCOSE LEVEL MONITORING SYSTEM DIACONT CONNECT WITH ACCESSORIES - The product is a glucose level monitoring system branded "Diacont," complete with test strips for the glucose monitoring system, Diacont version produced by OK Biotech Co. Ltd., Registration No. FSZ 2012/12700 (hereinafter referred to as test strips), electrochemical single-use (hereinafter referred to as test strip), a Diacont lancing device with sterile lancets produced by OK Biotech Co. Ltd., Registration No. FSZ 2010/06698 (hereinafter referred to as lancing device and sterile lancets), and control solutions of varying concentrations. The glucose concentration in the blood is determined after applying a blood sample to the test strip connected to the device.
The Diacont Connect glucometer detects the blood sample, determines the glucose concentration, and displays the reading on the screen.
Test strips are used to determine the glucose concentration in whole capillary blood. This is done after applying a blood sample to the test strip connected to the device.
The lancing device and lancets are intended for controlled skin puncture to obtain a capillary blood sample from the patient.
INTENDED USE
The product is intended for quantitative measurement of glucose levels in whole capillary blood for self-monitoring by patients with diabetes at home and for monitoring the effectiveness of diabetes control measures for healthcare professionals at the patient's treatment location.
FIELD OF APPLICATION
The product is intended for use in medical institutions as a multi-user system, as well as in home settings.
POTENTIAL USERS
Patients with diabetes and healthcare professionals.
PRINCIPLE OF OPERATION
Glucose present in the blood, upon contact with the test strip, undergoes an electrochemical reaction with the reagents of the test strip. The current level changes depending on the amount of glucose in the blood. The device measures the current strength, displays the measurement results on the screen in mmol/L, and saves them in memory.
TECHNICAL SPECIFICATIONS OF THE SYSTEM
The error for all technical parameters specified in this section is ±10%, unless otherwise stated.
Glucometer:
Dimensions: 99 mm ± (W) x 62 mm (H) x 20 mm (D)
Weight: 56 g (with batteries)
Test strip connector: 8 mm (W) x 1 mm (H) x 7 mm (insertion depth), 5 contacts in one plane
Measurement range: 1.1-33.3 mmol/L
Test time: 5 seconds.
Battery: two 3-volt lithium batteries, capacity 0.22Ah (Type CR 2032), diameter 20 mm, height 3.2 mm, weight: 2.8 g.
Battery life: designed for at least 1000 measurements
Units of measurement: mmol/L
Screen: LCD, dimensions of the visible part of the screen: 42 mm x 40 mm
Automatic power on: immediately after inserting the test strip ≤ 6 sec.
Automatic power off: no later than 3 minutes after the last user action.
Computer connection: USB port
Built-in Bluetooth: version 4.0, Frequency range: 2.4-2.48 GHz, operating radius - no more than 8 meters (without obstacles).
Acceptable hematocrit range: 20-60%
Built-in memory for 1000 results with date and time of the test
Sufficient blood volume for testing - 0.7 µL.
Test strips for the glucose monitoring system, Diacont version, produced by OK Biotech Co. Ltd., Registration No. FSZ 2012/12700
Test strips:
Width: 7.5 mm
Length: 30.0 mm
Strip contacts: 4 in one plane
Lancing device
Weight, g: 12
Product dimensions, mm: length 98; diameter 17.5
Sterile lancet
Needle gauge: 30G
Length of the needle in the protective plastic casing, mm: 22
Length of the effective part of the needle, mm: 1.9
Nominal outer diameter of the needle, mm: 0.32 (range of outer diameters from 0.298 to 0.320 mm)
Radius of the working parts' bluntness, mm no more than 0.03
Rockwell hardness, HRc no less than 30
Length of the lancet, mm: 32.5
Diameter of the protective cap, mm: 9.1
Height of the protective cap, mm: 9.5
Weight, g: 0.5
СИСТЕМА КОНТРОЛЯ УРОВНЯ ГЛЮКОЗЫ В КРОВИ DIACONT CONNECT С ПРИНАДЛЕЖНОСТЯМИ - Изделие представляет собой систему контроля уровня глюкозы в крови марки «Diacont», в комплекте с тест-полосками к системе контроля уровня глюкозы в крови, вариант исполнения Diacont производства OK Biotech Co. Ltd., РУ № ФСЗ 2012/12700 (далее - тест-полоски) электрохимического однократного применения (далее тест-полоска), скарификатором Diacont в комплекте со стерильными ланцетами производства OK Biotech Co. Ltd., РУ № ФСЗ 2010/06698 (далее - скарификатор и ланцеты стерильные) и контрольными растворами разной концентрации. Определение концентрации глюкозы в крови осуществляется после нанесения пробы крови на тест-полоску, подключенную к прибору.
Глюкометр Diacont Connect обнаруживает пробу крови, определяет концентрацию глюкозы и выводит показание на экран.
Тест-полоски используют для определения концентрации глюкозы в цельной капиллярной крови. Осуществляется после нанесения пробы крови на тест-полоску, подключенную к прибору.
Скарификатор и ланцеты предназначены для осуществления контролируемого прокола кожи с целью взятия образца капиллярной крови у пациента.
НАЗНАЧЕНИЕ
Изделие предназначено для количественного измерения уровня глюкозы в цельной капиллярной крови с целью самоконтроля больных сахарным диабетом в домашних условиях и мониторинга эффективности мер по контролю сахарного диабета для медицинских работников по месту лечения пациентов.
ОБЛАСТЬ ПРИМЕНЕНИЯ
Изделие предназначено для применения в медицинских учреждениях как многопользовательская система, а также в домашних условиях.
ПОТЕНЦИАЛЬНЫЕ ПОЛЬЗОВАТЕЛИ
Пациенты с заболеванием сахарный диабет и медицинские работники.
ПРИНЦИП РАБОТЫ
Глюкоза, содержащаяся в крови, при попадании на тест-полоску вступает в электрохимическую реакцию с реагентами тест-полоски. Уровень тока изменяется в зависимости от количества глюкозы в крови. Прибор измеряет силу тока, отображает результаты измерения на экране в единицах измерения ммоль/л и сохраняет их в памяти.
ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ СИСТЕМЫ
Погрешность для всех технических параметров, указанных в данном разделе, составляет ±10%, если не указано иное.
Глюкометр:
Размеры: 99 мм ± (Д) х 62 мм (Ш) х 20 мм (В)
Масса: 56 г. (с батарейками)
Разъем для тест-полоски: 8 мм (Ш) х 1мм (В) х 7 мм (глубина вставки), 5 контактов в одной плоскости
Диапазон измерений: 1,1-33,3 ммоль/л
Время теста: 5 секунд.
Батарейка: две 3-х вольтовые литиевые батарейки, емкость 0,22Ач (Тип CR 2032), диаметр 20 мм, высота 3,2 мм, масса: 2,8 г.
Срок службы батарейки: рассчитан не менее 1000 измерений
Единицы измерения: ммоль/л
Экран: LCD, габариты видимой части экрана: 42 мм х 40 мм
Автоматическое включение: сразу же после вставки тест-полоски ≤ 6 сек.
Автоматическое отключение: не позднее 3-х минут после последнего действия пользователя.
Связь с компьютером: USB порт
Встроенный Bluetooth: версия 4.0, Частотный диапазон: 2,4-2,48 ГГц, радиус работы - не более 8 метров (без препятствий).
Допустимый диапазон гематокрита: 20-60%
Встроенная память на 1000 результатов с датой и временем проведения теста
Достаточное количество крови для проведения теста - 0,7 мкл.
Тест-полоски к системе контроля уровня глюкозы в крови, вариант исполнения Diacont, производства OK Biotech Co. Ltd., РУ № ФСЗ 2012/12700
Тест-полоски:
Ширина: 7,5 мм
Длина: 30,0 мм
Контакты полосок: 4 в одной плоскости
Скарификатор
Масса, г: 12
Габариты изделия, мм: длина 98; диаметр 17,5
Ланцет стерильный
Калибр иглы: 30G
Длина иглы в защитной пластиковой оправе, мм: 22
Длина эффективной части иглы, мм: 1,9
Номинальный наружный диаметр иглы, мм: 0,32 (диапазон наружных диаметров от 0,298 до 0,320мм)
Радиусы притупления рабочих частей, мм не более 0,03
Твердость по Роквеллу, HRС не менее 30
Длина ланцета, мм: 32,5
Диаметр защитной крышки, мм: 9,1
Высота защитной крышки, мм: 9,5
Масса, г: 0,5
RU name Глюкометр diacont connect с принадлежностями
How we fulfill
Three checkpoints between the pharmacy shelf and your door. You see every one.
01
No grey-market middlemen, no warehouses we can't audit. Retail purchase, on demand, against your order.
02
A photo of your actual parcel in its original retail packaging lands in your inbox before it ships. Like this →
Real customer parcel
03
To 120+ countries. Most parcels arrive in 7–18 days.