01
A licensed Russian pharmacy buys it for you.
No grey-market middlemen, no warehouses we can't audit. Retail purchase, on demand, against your order.

Pharmacy item
SKU 118528
Other products by → Little Doctor International (S) Pte. Ltd.
All packagings
Selected · this page
LD51A
$62.76
Choose another
7 options
Tap any option to switch the active packaging — adding to cart applies to whatever is currently selected above.
Manufacturer leaflet
Facts from the printed manufacturer leaflet. Sections vary by drug — we only show what's actually in the box.
Indications
The device is intended for measuring systolic and diastolic blood pressure and determining pulse rate in patients aged 15 and older. The device is recommended for use by patients with unstable (variable) blood pressure or known hypertension at home as a supplement to medical monitoring.
Прибор предназначен для измерения систолического и диастолического артериального давления и определения частоты пульса у пациентов в возрасте от 15 лет. Прибор рекомендуется для использования пациентами с неустойчивым (непостоянным) артериальным давлением или известной артериальной гипертензией в домашних условиях как дополнение к медицинскому наблюдению.
Section: Method of Use and Dosage
TO OBTAIN ACCURATE READINGS OF YOUR ARTERIAL PRESSURE WHEN USING A DIGITAL DEVICE, IT IS NECESSARY TO:
MAINTAIN SILENCE DURING MEASUREMENT. Blood pressure measurement should be conducted in a calm, comfortable environment at room temperature. One hour before measurement, avoid eating, and for 1.5-2 hours, refrain from smoking, consuming stimulating drinks, and alcohol.
5. The accuracy of blood pressure measurement depends on the cuff of the device fitting your arm size. THE CUFF SHOULD NOT BE TOO SMALL OR, ON THE CONTRARY, TOO LARGE.
6. Repeat measurements are conducted at intervals of 3 minutes to restore blood circulation. However, individuals with pronounced atherosclerosis, due to significant loss of vessel elasticity, require a longer time between measurement intervals (10-15 minutes). This also applies to patients who have suffered from diabetes for a long time. For a more accurate determination of blood pressure, it is recommended to perform a series of 3 consecutive measurements and use the average value calculated by the device.
CORRECT POSITION DURING MEASUREMENT
1. Sit at a table so that during the blood pressure measurement your arm is resting on its surface. Ensure that the cuff placement on your shoulder is approximately at the same level as your heart, and that your arm is resting freely on the table and not moving.
2. You can measure your pressure while lying on your back. Look up, remain calm, and do not move during the measurement. Be sure to ensure that the cuff placement on your shoulder is approximately at the same level as your heart.
ЧТОБЫ ПОЛУЧИТЬ ПРАВИЛЬНЫЕ ПОКАЗАНИЯ ВАШЕГО АРТЕРИАЛЬНОГО ДАВЛЕНИЯ ПРИ ИСПОЛЬЗОВАНИИ ЦИФРОВОГО ПРИБОРА, НЕОБХОДИМО:
СОБЛЮДАТЬ ТИШИНУ ВО ВРЕМЯ ИЗМЕРЕНИЯ. Измерение артериального давления должно проводиться в спокойной комфортной обстановке при комнатной температуре. За час до измерения исключить прием пищи, за 1,5-2 часа курение, прием тонизирующих напитков, алкоголя.
5. Точность измерения артериального давления зависит от соответствия манжеты прибора размерам Вашей руки. МАНЖЕТА НЕ ДОЛЖНА БЫТЬ МАЛА ИЛИ, НАОБОРОТ, ВЕЛИКА.
6. Повторные измерения проводятся с интервалом 3 минуты, чтобы восстановить циркуляцию крови. Однако лицам, страдающим выраженным атеросклерозом, вследствие значительной потери эластичности сосудов требуется большее время между интервалами измерений (10-15 минут).
Это касается и пациентов, длительное время страдающих сахарным диабетом. Для более точного определения артериального давления рекомендуется производить серии из 3-х последовательных измерений и использовать расчитаное прибором среднее значение результатов измерений.
ПРАВИЛЬНАЯ ПОЗА ПРИ ИЗМЕРЕНИИ
1. Сядьте у стола так, чтобы во время измерения артериального давления Ваша рука лежала на его поверхности. Удостоверьтесь, что место наложения манжеты на плече находится приблизительно на одном уровне, что и сердце, и что рука свободно лежит на столе и не двигается.
2. Вы можете измерять давление и лежа на спине. Смотрите наверх, сохраняйте спокойствие и не двигайтесь во время измерения. Обязательно удостоверьтесь, что место наложения манжеты на плече находится приблизительно на том же уровне, что и сердце.
The device uses an oscillometric method to measure blood pressure and pulse rate. The cuff wraps around the arm and automatically inflates. The sensitive element of the device detects weak pressure fluctuations in the cuff caused by the expansion and contraction of the brachial artery in response to each heartbeat. The amplitude of the pressure waves is measured, converted into millimeters of mercury, and displayed as a digital value. The device has 2 memories with 90 cells each for storing measurement results. Please note that the device may not provide the specified measurement accuracy if it is used or stored at temperatures or humidity levels other than those specified in the "Technical Specifications" section of this manual. We warn of possible measurement errors with this blood pressure device in individuals with pronounced arrhythmia. Consult your doctor regarding blood pressure measurement in children. USED NEW TECHNOLOGIES LD Fuzzy Algorithm - a data processing algorithm that takes into account the characteristics of human heartbeat, ensuring higher accuracy. WHO Scale - classification of measurement results according to the recommendations of the World Health Organization (WHO). Arrhythmia indication - a special "W" icon on the device display indicates the presence of an irregular pulse. WARNING! This device is only permitted to be used with the following cuffs:
• compression cuff Cuff-LDA, size 25-36 cm (supplied with LD51 and LD51A),
• compression cuff Cuff-LDU, size 22-42 cm (supplied with LD51U),
• compression cuff Cuff-LDA2, size 32-43 cm (sold separately). TECHNICAL SPECIFICATIONS Measurement method oscillometric Liquid crystal indicator Pressure indication range in the cuff, mm Hg from 0 to 300 Measurement range: pressure in the cuff, mm Hg pulse rate, 1/min from 40 to 260 from 40 to 160 Limits of permissible absolute error in measuring air pressure in the compression cuff, mm Hg ±3 Limits of permissible relative error in measuring pulse rate, % ±5 Inflation automatic (air pump) Pressure release automatic Clock and date Yes - switchable Memory 2x90 measurements + average value of the last 3 for each memory block Power supply voltage, V 6 Type of power supply 4 AA (LR6) batteries or power supply of at least 600 mA Max. power consumption, W 3.6 Power supply LD-N057 (included in the LD51A set) Device lifespan (excluding cuff), years - 7 Lifespan of power supply (for LD51A and LD51U), years 7 Lifespan of cuff, years 3
Прибор использует осциллометрический метод измерения артериального давления и частоты пульса.
Манжета оборачивается вокруг плеча и автоматически накачивается. Чувствительный элемент прибора улавливает слабые колебания давления в манжете, производимые расширением и сокращением плечевой артерии в ответ на каждый удар сердца. Амплитуда волн давления измеряется, преобразовывается в миллиметры ртутного столба и выводится на дисплей в виде цифрового значения.
Прибор имеет 2 памяти по 90 ячеек для хранения результатов измерений. Обратите внимание на то, что прибор может не обеспечивать указанную точность измерения, если он используется или хранится при температуре или влажности иных, чем указаны в разделе "Технические характеристики" данного руководства. Предупреждаем о возможных ошибках при измерении данным прибором артериального давления у лиц с выраженной аритмией. Проконсультируйтесь у Вашего врача по поводу измерения артериального давления у ребенка. ИСПОЛЬЗУЕМЫЕ НОВЫЕ ТЕХНОЛОГИИ LD
Fuzzy Algorithm - алгоритм обработки данных измерений, позволяющий учитывать особенности сердцебиения человека, что обеспечивает более высокую точность.
Шкала ВОЗ - классификация результатов измерения согласно рекомендации Всемирной Организации Здравоохранения (ВОЗ). Индикация аритмии - специальный значок " W на дисплее прибора сообщает о наличии нерегулярного пульса.
ВНИМАНИЕ! Настоящий прибор допускается использовать только с указанными ниже манжетами:
• манжета компрессионная Cuff-LDA, размер 25-36 см (поставляется в комплекте с LD51 и LD51A),
• манжета компрессионная Cuff-LDU, размер 22-42 см (поставляется в комплекте с LD51U),
• манжета компрессионная Cuff-LDA2, размер 32-43 см (приобретается отдельно).
ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ
Метод измерения осциллометрический
Индикатор жидкокристаллический
Диапазон индикации давления в манжете, мм рт. ст. от 0 до 300
Диапазон измерения: давление в манжете, мм рт.ст. частоты пульса, 1/мин от 40 до 260 от 40 до 160
Пределы допускаемой абсолютной погрешности при измерении давления воздуха в компрессионной манжете, мм рт.ст. ±3
Пределы допускаемой относительной погрешности при измерении частоты пульса,% ±5
Нагнетание автоматическое (воздушный насос)
Сброс давления автоматический
Часы и дата Есть - отключаемые
Память 2х90 измерений + среднее значение 3-х последних для каждого блока памяти
Напряжение электропитания, В 6
Тип электропитания 4 элемента питания AA (LR6) или источник электропитания, не менее 600 мА
Макс. потребляемая мощность, Вт 3,6
Источник электропитания LD-N057 (входит в комплект LD51A
Срок службы прибора (без учета манжеты), лет - 7
Срок службы источника электропитания (для LD51A и LD51U), лет 7
Срок службы манжеты, лет 3
RU name Тонометр ld51a автомат
How we fulfill
Three checkpoints between the pharmacy shelf and your door. You see every one.
01
No grey-market middlemen, no warehouses we can't audit. Retail purchase, on demand, against your order.
02
A photo of your actual parcel in its original retail packaging lands in your inbox before it ships. Like this →
Real customer parcel
03
To 120+ countries. Most parcels arrive in 7–18 days.